National Stock Number (NSN) Output Data
Definition:
A TEST SET WHOSE PRIMARY FUNCTION IS TO MEASURE THE OPTICAL POWER LEVEL AVAILABLE FROM A LIGHT EMITTING SOURCE, SUCH AS LIGHT EMITTING DIODE, LASER DIODE. THIS TEST SET WILL ALSO MEASURE THE OPTICAL POWER LEVELS AT THE RECEIVER END OF AN OPTICAL FIBER.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
RJ-7620W/OPTGPIB | 0XGW3 | A | 5 | 9 | 4 | ZZ | ||
RJ-7620 | 51275 | A | 5 | 9 | 4 | MB | ||
RJ-7620 | 0XGW3 | A | 3 | 2 | 4 | ZZ | ||
RJ-7620-W/OPT-GPIB | 51275 | A | 5 | 9 | 4 | ZZ |
CAGE Information
Code | Company |
---|---|
0XGW3 | LASER PROBE, INC. |
51275 | ANRITSU INSTRUMENTS COMPANY DIV MBU |
Federal Supply Class
Title
OPTICAL INSTRUMENTS, TEST EQUIPM
Inclusions:
INCLUDES BINOCULARS; MAGNIFIERS; MICROSCOPES; PERISCOPES; TELESCOPES; OPTICAL ELEMENTS; SUCH AS LENS, PRISMS, WINDOWS; OPTICAL BENCHES AND ASSOCIATED DEVICES; ENDOSCOPES, FIBER OPTICS (NON-MEDICAL).
Exclusions:
EXCLUDES FIRE CONTROL INSTRUMENTS, OPTICAL; SURVEYING INSTRUMENTS, OPTICAL; PHOTOGRAMMETRIC INSTRUMENTS; OCTANTS; AND SEXTANTS; OPTICAL INSTRUMENTS INTEGRATED WITH FIRE CONTROL EQUIPMENT; OPTHALMOLOGICAL INSTRUMENTS; ELECTRONIC FIBER OPTIC TEST EQUIPMENT; MEDICAL ENDOSCOPES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FTLD | FUNCTIONAL DESCRIPTION | MEASURES TRUE ENERGY/PULSE FROM A SINGLE-SHOT TO 40HZ, PICCO JOULES TO JOULES, UV TO FAR-IR. SETS OF 10 TO 100 PULSES CAN BE STATISTICALLY AND ANALYZED, AND THE DATA CAN BE TRANSFERRED TO A COMPUTER VIA AN IEEE48 INTERFACE BUS. ACCEPTS 2 PROBES AND SIMUTANEOUSLY DISPLAYS THE ENERGY INCIDENT ON CHANNELS A AND B, AS WELL THE RATIO OF CHANNEL B/CHANNEL A. MAUFACTURES NAME ENERGY METER/RATIOMETER |
FEAT | SPECIAL FEATURES | 2HANNEL RATIOING CAPABILITY; HIGH RESOLUTION DISPLAY, 1 PART IN 3000; MEASUREMENT SPEEDS UP TO 40 PULSES/SECOND; PORM 5% ACCURACY; STATISTICAL ANALYSIS OF REPETITIVE PULSES: 10 OR 100 PULSE AVERAGE, MIN & MAX ENERGY AND STANDARD DEVIATION; 64 CHARACTER ALPHANUMERIC LCD DISPAY; DIGITAL COMPEMSATION FOR: WINDOW.FILTER/BEAM SPLITTER ATTENUATOR LOSS OR NORMALIZING DETECTOR RESPONSE (RANGE 0.1 TO 1.0); INTERCHANGEANLE WINDOW/FILTERS/ATTENUATORS; AUXILIARY WINDOW/FILTERS/ATTENUATORS; AUCILIARY ANALOG OUTPUTS |
RDAL | REFERENCE DATA AND LITERATURE | MANUFACTURERS COMMERCIAL LITERATURE |
ACYN | AC VOLTAGE RATING | 115.0 VOLTS NOMINAL AND 240.0 VOLTS NOMINAL |
ABGL | WIDTH | 10.000 INCHES NOMINAL |
AQXZ | OPERATING TEST CAPABILITY | 14 DECADES 10 TO THE -12TH (PICAJOULES) TO 100 JOULES DEPENDING ON WHICH OF 8 PROBES ARE USED |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
AQXY | TEST TYPE FOR WHICH DESIGNED | OPTICAL ENERGY MEASUREMENTS IN JOULES |
HGTH | HEIGHT | 4.000 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
FAAZ | PHASE | SINGLE |
ABRY | LENGTH | 12.000 INCHES NOMINAL |