National Stock Number (NSN) Output Data
NSN:
NIIN:
Item Name:
VENTURI METER
Definition:
A TUBE WHOSE INTERNAL SURFACE INCLUDES TWO TRUNCATED CONES CONNECTED TO EACH OTHER AT THE SMALL ENDS BY A VERY SHORT CYLINDER. IT IS INSTALLED IN FLUID PIPE LINES AND IS NORMALLY USED TO MEASURE THE FLOW OF LIQUID. IT MAY INCLUDE PRESSURE INDICATORS AND/OR CONNECTIONS.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PMT-1F-5M | 96790 | A | 3 | 2 | 3 | HD | ||
6321656 | 53711 | A | 7 | 2 | 1 | HD |
CAGE Information
Code | Company |
---|---|
53711 | NAVAL SEA SYSTEMS COMMAND |
96790 | BADGER METER INC INDUSTRIAL PRODUCTS |
Federal Supply Class
Title
LIQUID AND GAS FLOW, LIQUID LEVE
Inclusions:
INCLUDES LIQUID LEVEL FLOAT INSTRUMENTS; REVOLUTION COUNTERS; SPEEDOMETERS; ROTATION MEASURING INSTRUMENTS AND APPARATUS; OXYGEN FLOW INDICATORS; TACHOMETERS, INCLUDING ENGINE TACHOMETERS.
Exclusions:
EXCLUDES COMBINATION INSTRUMENTS; (FSC 6695); METEOROLOGICAL INSTRUMENTS (FSC 6660); AND AUTOMATIC CONTROL VALVES (FSG 48).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQCJ | THROAT DIAMETER | 4.550 INCHES MINIMUM AND 4.610 INCHES MAXIMUM |
BHCY | TUBE END SIZE | 4.58 IN ID |
BHCC | LIQUID FLOW RATE | 0.0 GALLONS PER MINUTE MINIMUM AND 500.0 GALLONS PER MINUTE MAXIMUM |
ABHP | OVERALL LENGTH | 10.970 INCHES MINIMUM AND 11.170 INCHES MAXIMUM |
AMWP | PRESSURE GAGE | NOT INCLUDED |
APTD | END TYPE | PLAIN |
AGAV | END ITEM IDENTIFICATION | HD-1155 COOLER,WATER |
BHCZ | PRESSURE GAGE CONNECTION | PROVIDED |