Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
95104 | ALCATEL USA INC. DIV WTPG |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWJS | WINDING OPERATING VOLTAGE | 102.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
FEAT | SPECIAL FEATURES | PRIMARY HAS SPECIAL TAP USED TO VARY SECONDARY OUPUTRATINGS W.PRIMARY V |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
ABMK | OVERALL WIDTH | 1.312 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.750 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
ABHP | OVERALL LENGTH | 1.312 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.5 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 6.20 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE SECONDARY |
AAJD | THREAD CLASS (NON-CORE) | 2A SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TAB, SOLDER LUG |