Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , PRESSURE
Definition:
A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; AND SWITCH, SENSITIVE.
CAGE Information
Code | Company |
---|---|
D0589 | BUCHER SCHOERLING GMBH |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 24.0 DC AT SEA LEVEL SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET |
FEAT | SPECIAL FEATURES | TEFLON DIAPHRAGM,316 STAINLESS STEEL FITTING |
CQJB | PROOF PRESSURE | 2000.00 POUNDS PER SQUARE INCH GAGE |
CTYM | CONTACT ADJUSTMENT RANGE | +10.00/+340.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.625 INCHES NOMINAL |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |