Part Number
Part Number:
NSN:
NIIN:
Item Name:
FLASHER , THERMAL
Definition:
AN ITEM DESIGNED TO COMPLETE, INTERRUPT OR CHANGE THE CONNECTIONS IN ONE OR MORE ELECTRICAL LIGHTING CIRCUITS IN ACCORDANCE WITH A PREDETERMINED TIME CYCLE. IT IS ACTUATED BY THE EFFECT OF HEAT GENERATED BY CURRENT PASSING THROUGH ITS CIRCUIT(S). EXCLUDES CONTROL, DIRECTIONAL SIGNAL LIGHT, AUTOMOTIVE, AND SWITCH THERMOSTATIC. SEE ALSO FLASHER, SOLID STATE.
CAGE Information
Code | Company |
---|---|
72914 | GRIMES AEROSPACE COMPANY DBA HONEYWE |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
APCS | ADJUSTABILITY | ADJUSTABLE |
ABMK | OVERALL WIDTH | 3.000 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
ACYN | AC VOLTAGE RATING | 120.0 VOLTS NOMINAL |
ALGC | MOUNTING CONFIGURATION | FOUR 0.180 IN. DIA MTG HOLES ON 2.000 IN. BY 2.500 IN. MTG CENTERS |
APFP | CONTROLLED CIRCUIT QUANTITY | 1 |
APCM | ACTUATION TYPE | ELECTROMECHANICAL |
ABKW | OVERALL HEIGHT | 2.500 INCHES NOMINAL |
APFN | ACCURACY IN PERCENT | 10.0 |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
APFM | FAILURE AUTOMATIC CIRCUIT CONDITION | OFF |
APFH | FLASHING RATE | 30 PER MINUTE NOMINAL |
ABHP | OVERALL LENGTH | 3.750 INCHES NOMINAL |
AARA | TERMINAL QUANTITY | 1 |
FAAZ | PHASE | SINGLE |
AARB | TERMINAL TYPE | CONNECTOR, RECEPTACLE |