Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
GENERATOR SET , DIESEL ENGINE

Definition:

A GENERATOR SET USING A DIESEL ENGINE AS THE PRIME MOVER. EXCLUDES GENERATOR SET, DIESEL ENGINE, TRAILER MOUNTED.

CAGE Information

Code Company
30554 DEPARTMENT OF DEFENSE PROJECT MANAGE

Federal Supply Class

Title

GENERATORS AND GENERATOR SETS, E

Inclusions:

INCLUDES ENGINE, TURBINE, WIND, AND HAND DRIVEN GENERATOR SETS AND AUXILIARY AIRCRAFT GENERATORS.

Exclusions:

EXCLUDES MOTOR-CONVERTERS; MOTOR-GENERATOR SETS; ENGINE GENERATORS; ENGINE ACCESSORY GENERATORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AENK COOLING METHOD RADIATOR
AENK COOLING METHOD RADIATOR
AYHD POWER FACTOR IN PERCENT 80.0
ZZZT NONDEFINITIVE SPEC/STD DATA 1 TYPE AND 2 CLASS
ABMK OVERALL WIDTH 35.750 INCHES NOMINAL
AYSA CRANKING VOLTAGE IN VOLTS 24.0
AKNA INCLOSURE TYPE FULLY INCLOSED
AZCB HOUSING TYPE INCLOSED
AMWJ WINTERIZATION FEATURE NOT INCLUDED
AYHE EXCITOR TYPE SEPARATELY EXCITED
AYHF EXCITOR INCLUDED
ABKW OVERALL HEIGHT 36.000 INCHES NOMINAL
AZCM TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION 90.0
ABHP OVERALL LENGTH 69.750 INCHES NOMINAL
AYHC LINE TO NEUTRAL VOLTAGE IN VOLTS 120.0 AND 240.0
FAAZ PHASE THREE
AZBP PRIME MOVER IDENTIFYING NUMBER 72-2222 PART NO.
AZBN PRIME MOVER MANUFACTURER NAME PROJECT MANAGER-MOBILE ELECTRIC POWER
AAXX MOUNTING TYPE SKID
AYHB LINE TO LINE VOLTAGE IN VOLTS 208.0 AND 416.0
AYQZ PRIME MOVER STARTING METHOD ELECTRIC MOTOR
AERL MAXIMUM WEIGHT CAPACITY 3000.000 POUNDS
AZKT RADIO INTERFERENCE SUPPRESSION INCLUDED
ACZB FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
AZCL AMBIENT TEMP IN DEG CELSIUS -31.7 AND 51.7
AZBM AUTOMATIC STARTING FEATURE NOT PROVIDED
AAXS PRIME MOVER COOLING MEDIUM LIQUID
ACDC CURRENT TYPE AC
AYGY AC WATTAGE RATING 12.5 KILOWATTS AND 15.0 KILOWATTS

Similar Parts