CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

CAGE Information

Code Company
74193 EATON CORP HEINEMANN PRODUCTS COMMER

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
BBRJ SPECIAL HANDLING FEATURE MAGNETIC
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT SINGLE LOCATION
CPRZ AUXILIARY SWITCH FUNCTION AND QUANTITY 1 ALARM
AAQL BODY STYLE SINGLE POLE TYPE
CSWP SWITCH VOLTAGE RATING AND TYPE IN VOLTS 115.0 AC AND 50.0 DC
AFJN FRAGILITY FACTOR MODERATELY RUGGED
TTQY TERMINAL TYPE AND QUANTITY 2 THREADED STUD
CSSX SWITCH CURRENT RATING AND TYPE IN AMPS 5.0 AC AND 1.0 DC
CPSM INTERNAL TRIP RELEASE CONFIGURATION SERIES TRIP SINGLE LOCATION
CPRR MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
CPRJ TRIP RELEASE METHOD MAGNETIC SINGLE LOCATION
ADAQ BODY LENGTH 2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM
AEGJ SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
TEST TEST DATA DOCUMENT 05869-711570 DRAWING
CQSM SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
AJEC BOSS HEIGHT 0.125 INCHES MINIMUM AND 0.155 INCHES MAXIMUM
ADTV CASE MATERIAL PLASTIC
AEBY DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 2.047 INCHES MINIMUM AND 2.077 INCHES MAXIMUM
AKPX POLE QUANTITY 1
CPRQ RESET METHOD MANUAL
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 10.0 AMPERES DC SINGLE LOCATION
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 2.775 INCHES MINIMUM AND 2.955 INCHES MAXIMUM
CPRG MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS 2000.0 DC SINGLE LOCATION
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 50.0 DC SINGLE LOCATION
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 THREADED HOLE
THSD THREAD SERIES DESIGNATOR UNC
CRTK SWITCH TERMINAL TYPE TAB, SOLDER LUG
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.925 INCHES MINIMUM AND 1.955 INCHES MAXIMUM
CPRW ACTUATOR FUNCTION TRIP-RESET
APNQ ARC QUENCHING METHOD MAGNETIC BLOWOUT
PKWT UNPACKAGED UNIT WEIGHT 0.312 POUNDS
CQWN TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT 3.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 10.000 MAXIMUM AT 200 PCT SINGLE LOCATION
CPRX ACTUATOR POSITION DESIGNATION AT POLE ONE
CQXF INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED SHOCK RESISTANT AND VIBRATION RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
CMLP THREAD QUANTITY PER INCH 32
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY SINGLE LOCATION
ADAT BODY WIDTH 0.735 INCHES MINIMUM AND 0.765 INCHES MAXIMUM
CPRN ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT 125.0 SINGLE LOCATION
CQJX NOMINAL THREAD SIZE 0.138 INCHES

Similar Parts

70-132-56MG6 , 7013256MG6 , 5925-00-869-0752 , 5925008690752 , 008690752