RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
01121 ROCKWELL AUTOMATION INC.

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
ABMK OVERALL WIDTH 3.125 INCHES NOMINAL
ABHP OVERALL LENGTH 3.375 INCHES NOMINAL
ABKW OVERALL HEIGHT 5.312 INCHES NOMINAL
CTYK ANGLE BETWEEN ADJACENT MOUNTING FACILITIES 120.0 DEGREES NOMINAL SINGLE MOUNTING FACILITY
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 4 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
APCN COIL QUANTITY 1
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 10.0 AMPERES AC RESISTIVE LOAD
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY
AXHR MOUNTING FACILITY TYPE AND QUANTITY 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
TTQY TERMINAL TYPE AND QUANTITY 14 PIN ALL FUNCTIONS
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 120.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 600.0 AC
CQYJ MOUNTING FACILITY PATTERN CIRUCLAR SINGLE MOUNTING FACILITY