Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
01121 ROCKWELL AUTOMATION INC.

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKDX WINDING QUANTITY 1
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.156 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABMK OVERALL WIDTH 2.125 INCHES NOMINAL
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 300.0 AC AND 115.0 DC
AJSS FREQUENCY IN HERTZ 60.0 NOMINAL
ABHP OVERALL LENGTH 3.500 INCHES NOMINAL
APCN COIL QUANTITY 1
CQYJ MOUNTING FACILITY PATTERN TRIANGLE SINGLE MOUNTING FACILITY
ABKW OVERALL HEIGHT 5.438 INCHES NOMINAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 4 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 1.1 AMPERES AC RESISTIVE LOAD AND 1.1 AMPERES DC RESISTIVE LOAD
CSQJ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE 4.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
APNP DUTY TYPE CONTINUOUS
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 120.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING

Similar Parts