Part Number
Part Number:
NSN:
NIIN:
Item Name:
OSCILLATOR , CRYSTAL CONTROLLED
Definition:
AN OSCILLATOR WHOSE OPERATING FREQUENCY(IES) IS CONTROLLED BY A CRYSTAL UNIT, QUARTZ. FOR AN OSCILLATOR CONTROLLED BY A DEVICE OTHER THAN A CRYSTAL, SEE OSCILLATOR (1), NONCRYSTAL CONTROLLED. SEE ALSO GENERATOR, SIGNAL; AND CALIBRATOR, FREQUENCY. EXCLUDES FREQUENCY SUPPLY, TELEPHONE CARRIER; RESONATOR, TUNING FORK; AND OSCILLATOR, PULSE DELAY.
CAGE Information
Code | Company |
---|---|
00136 | VECTRON INTERNATIONAL INC. |
Federal Supply Class
Title
ELECTRONIC MODULES
Inclusions:
Exclusions:
EXCLUDES MICROCIRCUITS; ELECTRONIC TEST EQUIPMENT PLUG-IN UNITS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFGA | OPERATING TEMP RANGE | -40.0/+70.0 DEG CELSIUS |
BJBP | CONNECTION TYPE AND LOCATION | TERMINAL STUD BOTTOM |
AQZF | CONTROL TYPE | LOCAL |
ABHP | OVERALL LENGTH | 1.940 INCHES MINIMUM AND 2.060 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 1.940 INCHES MINIMUM AND 2.060 INCHES MAXIMUM |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE |
ADZC | ENVIRONMENTAL PROTECTION | MOISTURE PROOF AND SHOCK RESISTANT AND VIBRATION |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+500.0 |
AFDN | VIBRATION RESISTANCE AMPLITUDE | 10.0 GRAVITATIONAL UNITS |
AFDP | SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS | 75.0 |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
BJBN | SHOCK PULSE DURATION TIME | 6.0 MILLISECONDS |
AJKH | IDENTIFICATION DESIGNATOR | 77C716205P002-03538 |
BHTK | SIGNAL VOLTAGE RATING PER CHANNEL | -15.000 VOLTS INPUT MINIMUM AND 5.000 VOLTS INTERSTAGE MINIMUM |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 4 TERMINAL STUD EXTERNAL |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED |
BHTH | ATTENUATION IN DECIBELS | NOT RATED |
AMQY | INSTALLATION DESIGN | MODULE |
BHTL | OVERALL GAIN | NOT RATED |
BHTB | FREQUENCY PER CHANNEL | 15.6672 MEGAHERTZ CERIUM MEGAHERTZ |
ABKW | OVERALL HEIGHT | 0.440 INCHES MINIMUM AND 0.560 INCHES MAXIMUM |
BHTJ | AVERAGE POWER RATING PER CHANNEL | NOT RATED |
BHSX | CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
BHTD | FREQUENCY ADJUSTMENT TYPE | CONTINUOUS |
BHTK | SIGNAL VOLTAGE RATING PER CHANNEL | 0.500 VOLTS INPUT PRESET AND 2.400 VOLTS INTERSTAGE PRESET |
BHTN | IMPEDANCE RATING PER CHANNEL | NOT RATED |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC |