Part Number
Part Number:
NSN:
NIIN:
Item Name:
TOXIC GAS-VAPOR DETECTOR KIT
CAGE Information
Code | Company |
---|---|
63882 | SENSIDYNE LP |
Federal Supply Class
Title
HAZARD-DETECTING INSTRUMENTS AND
Inclusions:
INCLUDES RADIAC EQUIPMENT; GAS DETECTING EQUIPMENT; LAND MINE DETECTING EQUIPMENT.
Exclusions:
EXCLUDES MANUAL GAS ALARMS (FSC 6350).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TEXT | GENERAL CHARACTERISTICS ITEM DESCRIPTION | A GAS DETECTOR SYSTEM CONSISTING OF A TOXIC GAS AND DETECTOR PUMP,CARRYING CASE,LUBRICANT,RUBBER TUBE HOLDERS AND INSTRUCTIONS FOR USE; PUMP,A POSITIVE DISPLACEMENT TYPE OPERATED WITH VARIABLE ORIFICES WHICH PROVIDE FLOW RATES OF 25 TO 200 CC/MINUTE HAVE A MINIMUM CAPABILITY TO SAMPLE TOXIC METAL GAS OR VAPOR,ORGANIC AND INORGANIC GAS,VAPOR OR MIST; CAPABLE OF CHANGE FROM A HIGH RATE TO LOW RATE OF FLOW SAMPLING WITH A FLOW METER VARIATION OF NO MORE THAN PLUS OR MINUS 5 PCT WHEN USING 0.45 TO 5 MICRONFILTE MEDIA; CONSTRUCTED OF A SUITABLE MATERIAL TO RESIST DETERIORATION CAUSED BY SAMPLING CORROSIVE GASES AND VAPORS; HANDLE LOCK AT 50 OR 100 CC INTAKE VOLUME; MEASURE APPROXIMATELY 8 INCHES IN LENGTH AND WEIGHS 10 OUNCES; COMPATIBLE WITH GAS DETECTION TUBES |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | TOXIC GAS-VAPOR DETECTOR KIT POSITIVE DISPLACEMENT PUMP |