Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
81541 |
SENSATA TECHNOLOGIES MARYLAND INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
ADAQ |
BODY LENGTH |
1.750 INCHES MAXIMUM |
ADAQ |
BODY LENGTH |
1.750 INCHES MAXIMUM |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP ALL LOCATIONS |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.688 INCHES NOMINAL |
AKPX |
POLE QUANTITY |
2 |
THSD |
THREAD SERIES DESIGNATOR |
UNEF |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
50.0 DC ALL LOCATIONS |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.688 INCHES NOMINAL |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
THD BUSHING W/PANEL SEAL |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQJX |
NOMINAL THREAD SIZE |
0.375 INCHES |
CPRL |
TRIP RELEASE CHARACTERISTIC |
INSTANTANEOUS ALL LOCATIONS |
ADAT |
BODY WIDTH |
0.938 INCHES NOMINAL |
CPRQ |
RESET METHOD |
MANUAL |
CPRP |
ULTIMATE TRIP TIME PER POLE IN SECONDS |
0.035 MAXIMUM ALL LOCATIONS |
TTQY |
TERMINAL TYPE AND QUANTITY |
4 WIRE HOOK |
CPRW |
ACTUATOR FUNCTION |
RESET |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC ALL LOCATIONS |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.500 INCHES NOMINAL |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT EACH POLE |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
HERMETICALLY SEALED |
AAQL |
BODY STYLE |
MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADTV |
CASE MATERIAL |
METAL |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT ALL LOCATIONS |
ABXD |
BUSHING LENGTH |
0.450 INCHES NOMINAL |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
150.0 ALL LOCATIONS |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 TOGGLE |
CPRY |
EXTERNAL ACTUATOR LINKAGE ARRANGEMENT |
ONE AND TWO LINKED |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
3.0 AMPERES DC ALL LOCATIONS |