Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
19207 |
U S ARMY TANK AUTOMOTIVE COMMAND AMS |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
TEST |
TEST DATA DOCUMENT |
81348-MIL-C-13516 SPECIFICATION |
TEST |
TEST DATA DOCUMENT |
81348-MIL-C-13516 SPECIFICATION |
ABHP |
OVERALL LENGTH |
3.156 INCHES NOMINAL |
ADAT |
BODY WIDTH |
1.875 INCHES NOMINAL |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 SCREW |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.406 INCHES NOMINAL |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.062 INCHES NOMINAL |
CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
CPRQ |
RESET METHOD |
AUTOMATIC |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
APNQ |
ARC QUENCHING METHOD |
AIR |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
105.0 AMPERES DC SINGLE LOCATION |
THSD |
THREAD SERIES DESIGNATOR |
UNF |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
2000.0 DC SINGLE LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
MOISTURE RESISTANT |
CPRJ |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
30.000 NOMINAL AT 200 PCT SINGLE LOCATION |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
28.0 DC SINGLE LOCATION |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
125.0 SINGLE LOCATION |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.406 INCHES NOMINAL |