Part Number
Part Number:
NSN:
NIIN:
Item Name:
THERMOSTAT , FLOW CONTROL
Definition:
AN AUTOMATIC REGULATING DEVICE WHICH CONTROLS THE FLOW OF FLUIDS OR GASES BY ACTUATING A VALVE OR SHUTTER FOR HEATING OR COOLING PURPOSES. MAY BE ADJUSTABLE, OR SET TO OPERATE AT A DEFINITE PRESSURE. EXCLUDES CONTROL, HUMIDITY; CONTROL, TEMPERATURE INDICATING; AND SWITCH, THERMOSTATIC.
CAGE Information
Code | Company |
---|---|
75545 | LAWLER MANUFACTURING CO. INC. |
Federal Supply Class
Title
PRESSURE, TEMPERATURE, AND HUMID
Inclusions:
INCLUDES THERMOMETERS, INCLUDING ENGINE THERMOMETERS; PRESSURE GAGES; THERMOCOUPLE LEADS; RESISTANCE BULBS.
Exclusions:
EXCLUDES CLINICAL THEROMETERS; (FSC 6515); THERMOSTATIC AND DIFFERENTIAL PRESSURE SWITCHES (FSC 5930); AND METEOROLOGICAL INSTRUMENTS (FSC 6660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AGWM | LARGEST OUTSIDE DIAMETER | 4.3125 INCHES NOMINAL |
AGWM | LARGEST OUTSIDE DIAMETER | 4.3125 INCHES NOMINAL |
AWPA | THERMOSTAT TYPE | LIQUID EXPANSION |
ADJH | MOUNTING METHOD | FLANGE |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | ACTUATOR,12.0 IN. LG 1,CAPILLARY TUBE,15.0 FT LG 1 |
AWTM | OPENING TEMP RATING | 80.0 DEG FAHRENHEIT NOMINAL |
ABKW | OVERALL HEIGHT | 2.125 INCHES NOMINAL |
ALCD | USAGE DESIGN | TO OPERATE FLOW CONTROL VALVE |
AWTN | OPERATING TEMP RATING | 120.0 DEG FAHRENHEIT NOMINAL |
AWTP | SPRING OPERATED PRESSURE RELIEF | NOT PROVIDED |