Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , CURRENT

Definition:

AN ITEM CONSISTING OF ONE OR MORE WINDINGS, DESIGNED TO BE PLACED NEAR OR CONNECTED IN SERIES WITH AN ALTERNATING CURRENT POWER LINE TO MEASURE THE CURRENT PASSING THROUGH THE LINE BY MEANS OF A METER; OR TO CONTROL THE CURRENT PASSING THROUGH THE LINE BY MEANS OF A CONTROL DEVICE. EXCLUDES TRANSFORMER, POWER, CURRENT REGULATING.

CAGE Information

Code Company
90536 LOCKHEED MARTIN CORPORATION DBA LOCK

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ACZB FREQUENCY RATING 5.0 KILOHERTZ NOMINAL SINGLE COMPONENT
TTQY TERMINAL TYPE AND QUANTITY 7 WIRE LEAD
CWJS WINDING OPERATING VOLTAGE 1.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ADAV OVERALL DIAMETER 1.100 INCHES MAXIMUM
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CBME CUBIC MEASURE (NON-CORE) 2.37 CUBIC INCHES
AKNA INCLOSURE TYPE OPEN
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP
ADAQ BODY LENGTH 0.625 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 17.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY

Similar Parts

7056976-00 , 705697600 , 5950-01-018-8826 , 5950010188826 , 010188826