Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
FUSE , INCLOSED LINK

Definition:

A FUSE IN WHICH THE ELEMENT IS INCLOSED IN A BODY OF OTHER THAN CYLINDRICAL SHAPE. IT MAY INCLUDE VISUAL INDICATION THAT THE FUSIBLE ELEMENT IS SEVERED. FOR CYLINDRICAL ITEMS, SEE FUSE, CARTRIDGE. EXCLUDES FUSE, OPEN LINK; AND FUSE LINK, ELECTRICAL.

CAGE Information

Code Company
30086 SPD ELECTRICAL SYSTEMS INC

Federal Supply Class

Title

FUSES, ARRESTORS, ABSORBERS, AND

Inclusions:

INCLUDES FUSEHOLDERS; FUSE BOXES; FUSE POSTS; FUSE LINKS; FUSE BLOCKS; CURRENT LIMITERS; CORONA BALLS; ELECTROSTATIC DISCHARGERS.

Exclusions:

EXCLUDES CIRCUIT BREAKERS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AFWY TERMINAL THICKNESS 0.750 INCHES NOMINAL
AFWY TERMINAL THICKNESS 0.750 INCHES NOMINAL
ABKW OVERALL HEIGHT 1.000 INCHES NOMINAL
ADTV CASE MATERIAL CERAMIC
ABDN TERMINAL SURFACE TREATMENT NICKEL PLATED
ABTB MOUNTING HOLE DIAMETER 0.625 INCHES NOMINAL
AEBJ CONTINUOUS CURRENT RATING IN AMPS 3000.000
AFXE MAXIMUM VOLTAGE RATING IN VOLTS 600.0 AC
ABJT TERMINAL LENGTH 3.469 INCHES NOMINAL
CSQN SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS 200000.0
ABMK OVERALL WIDTH 5.000 INCHES NOMINAL
AFWW TERMINAL WIDTH 4.000 INCHES NOMINAL
AFXF CIRCUIT OVER-CURRENT INTERRUPTION TYPE NORMAL INSTANTANEOUS
ABHP OVERALL LENGTH 10.750 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 5.750 INCHES NOMINAL
AFXH INTERRUPTION INDICATOR METHOD OPAQUE BODY
AAQL BODY STYLE LIMITER W/HOLE

Similar Parts

710316A10 , 710316A10 , 5920-00-009-8186 , 5920000098186 , 000098186