Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
06481 | NORTHROP GRUMMAN GUIDANCE AND ELECTR |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CBME | CUBIC MEASURE (NON-CORE) | 17.7 CUBIC INCHES |
AEHZ | MAXIMUM OPERATING TEMP | 100.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABKW | OVERALL HEIGHT | 2.700 INCHES MAXIMUM |
CQLC | WINDING TAP LOCATION (NON-CORE) | NEUTRAL TAP SINGLE COMPONENT ALL SECONDARY |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT AND MOISTURE RESISTANT AND VIBRATION RESISTANT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 199.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 21.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 5.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 25.0 WATTS SINGLE COMPONENT |
ABHP | OVERALL LENGTH | 3.500 INCHES MAXIMUM |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 2.8 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 22.40 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 12 TURRET |
ABMK | OVERALL WIDTH | 1.875 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.151 INCHES NOMINAL SINGLE GROUP |