Part Number
Part Number:
NSN:
NIIN:
Item Name:
RESISTOR , THERMAL
Definition:
A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
CAGE Information
Code | Company |
---|---|
95104 | ALCATEL USA INC. DIV WTPG |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABHP | OVERALL LENGTH | 0.625 INCHES NOMINAL |
AEWK | MAXIMUM CURRENT RATING | 25.00 AMPERES |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
ADAR | BODY OUTSIDE DIAMETER | 0.219 INCHES NOMINAL |
CQWD | ZERO POWER RESISTANCE | 900.000 OHMS |
AEHX | MAXIMUM POWER DISSIPATION RATING | 1.00 MILLIWATTS |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 120.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
STYL | STYLE DESIGNATOR | ROD |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ADAQ | BODY LENGTH | 0.625 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
ADAV | OVERALL DIAMETER | 0.219 INCHES NOMINAL |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 509.0 OHMS 1ST RESISTANCE-TEMPERATURE POINT |
AEBT | TERMINAL DIAMETER | 0.024 INCHES NOMINAL |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 352.0 OHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 223.0 OHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 125.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 80.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 213.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
ABJT | TERMINAL LENGTH | 1.000 INCHES NOMINAL |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0/+10.0 |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 150.0 DEG CELSIUS |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0/+10.0 ALL RESISTANCE-TEMPERATURE POINTS |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 150.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |