Part Number
Part Number:
NSN:
NIIN:
Item Name:
REACTOR
Definition:
A COIL OR COILS USUALLY CONSTRUCTED WITH CORES HAVING LOW MAGNETIC RELUCTANCE, WHOSE PRIMARY PURPOSE IS TO FURNISH AN INDUCTIVE IMPEDANCE IN POWER OR AUDIO FREQUENCY CIRCUIT RANGING FROM ZERO TO 20 KILOHERTZ (KILOCYCLES). INCLUDES AUDIO FREQUENCY AND POWER FILTER CHOKES, AUDIO REACTORS AND SWINGING CHOKES. DOES NOT INCLUDE TRANSFORMERS OR COILS USED ABOVE AUDIO FREQUENCY RANGE. EXCLUDES SATURABLE REACTOR. FOR REACTORS WITH AIR CORES, SEE COIL (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
04939 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ACYV | INDUCTANCE RATING | 31.46 MICROHENRIES MINIMUM SINGLE COMPONENT ALL WINDING |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING AND WINDING TURNS SINGLE COMPONENT ALL WINDING |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AKDX | WINDING QUANTITY | 2 SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
CRGS | DC RESISTANCE RATING IN OHMS | 0.050 SINGLE COMPONENT ALL WINDING |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
ACYF | INDUCTANCE TYPE | FIXED |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CQPZ | WINDING CONDUCTOR SIZE | 0.01790 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT ALL WINDING |
ABHP | OVERALL LENGTH | 0.500 INCHES MAXIMUM |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 0.055 POUNDS |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
ABHY | TURN QUANTITY | 20 SINGLE COMPONENT ALL WINDING |
ADAV | OVERALL DIAMETER | 0.880 INCHES MAXIMUM |
CRBZ | WINDING OPERATING CURRENT | 0.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT ALL WINDING |