Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 55.0 OHMS NOMINAL SINGLE WINDING |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ABKW | OVERALL HEIGHT | 5.615 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.687 INCHES NOMINAL SINGLE MOUNTING FACILITY |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC MOTOR LOAD AND 100.0 AMPERES DC MOTOR LOAD |
APCN | COIL QUANTITY | 1 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CBME | CUBIC MEASURE | 99.203 CUBIC INCHES |
ABMK | OVERALL WIDTH | 3.365 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED RELEASE TIME |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC RESISTIVE LOAD AND 100.0 AMPERES DC RESISTIVE LOAD |
APNQ | ARC QUENCHING METHOD | AIR |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD ALL FUNCTIONS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
APNP | DUTY TYPE | CONTINUOUS |
ABHP | OVERALL LENGTH | 4.250 INCHES MAXIMUM |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
ADTV | CASE MATERIAL | METAL |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CRXH | TIME DELAY | 0.06 SECONDS MAXIMUM FIXED OPERATE TIME |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS24168 GOVERNMENT STANDARD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES DC INDUCTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 750.0 MILLIAMPERES AC LAMP LOAD AND 750.0 MILLIAMPERES DC LAMP LOAD |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |