Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OF MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, NONWIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND, PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.700 INCHES NOMINAL |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
ABWV | SHAFT DIAMETER | 0.140 INCHES MAXIMUM |
AAPN | SECTION QUANTITY | 1 |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.25 FREE AIR SINGLE SECTION |
ADAT | BODY WIDTH | 0.297 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
ADAQ | BODY LENGTH | 1.297 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.390 INCHES MAXIMUM |
ABJT | TERMINAL LENGTH | 0.250 INCHES MINIMUM |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 17.0 OHMS SINGLE SECTION |
AAQL | BODY STYLE | RECTANGULAR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.300 INCHES NOMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
ABXF | SHAFT LENGTH | 0.063 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 50.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |