Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

CAGE Information

Code Company
98927 ELECTRONIC SPECIALTY CORP RELAY DIV

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 28.0 DC
AKDX WINDING QUANTITY 1
ABKW OVERALL HEIGHT 0.410 INCHES NOMINAL
ABHP OVERALL LENGTH 1.490 INCHES NOMINAL
APCN COIL QUANTITY 1
APNA WINDING DC RESISTANCE RATING 36.0 OHMS NOMINAL SINGLE WINDING
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY
ADZC ENVIRONMENTAL PROTECTION HERMETIC
ABMK OVERALL WIDTH 1.470 INCHES NOMINAL
AEBV UNTHREADED MOUNTING HOLE DIAMETER 0.134 INCHES NOMINAL SINGLE MOUNTING FACILITY
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.200 INCHES NOMINAL SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 7.0 AMPERES DC RESISTIVE LOAD
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING

Similar Parts

71GB88R , 71GB88R , 5945-00-460-9951 , 5945004609951 , 004609951