Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
05869 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ARNH | OPERATING POSITION | ALL POSITIONS |
ADAT | BODY WIDTH | 2.950 INCHES MINIMUM AND 3.050 INCHES MAXIMUM |
AFGQ | FREQUENCY RANGE RATING | +7.000/+11.000 GIGAHERTZ |
AKSA | WAVEGUIDE FLANGE DESIGNATION | UG-1493/U |
AWNC | INTERNAL OPERATING PRESSURE | 100.0 POUNDS PER SQUARE INCH GAGE |
AKNK | VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +7.000/+11.000 GIGAHERTZ |
ABHP | OVERALL LENGTH | 7.470 INCHES MINIMUM AND 7.530 INCHES MAXIMUM |
BFMF | COOLING METHOD | FORCED LIQUID |
AJDB | POWER RATING | 1.200 KILOWATTS AVERAGE |
AKRZ | TERMINATION TYPE | WAVEGUIDE FLANGE |
AAXT | COOLING SYSTEM COOLANT FLOW RATE | 2.0 GALLONS PER MINUTE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AWNL | INPUT COOLANT TEMP | 85.0 DEG CELSIUS |