TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
05869 RAYTHEON COMPANY DBA RAYTHEON

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 0.250 POUNDS
CWJS WINDING OPERATING VOLTAGE 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
CWJS WINDING OPERATING VOLTAGE 9.80 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO THREE PHASE SINGLE COMPONENT
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
CQJX NOMINAL THREAD SIZE 0.138 INCHES SINGLE GROUP
ACZF MAXIMUM TRANSFORMER POWER RATING 1.5 VOLT-AMPERE SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZD TRANSFORMER WINDING CONNECTION TYPE WYE-DELTA
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
ADAT BODY WIDTH 1.310 INCHES MAXIMUM
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 65.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY
ADAQ BODY LENGTH 2.380 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 14 TAB, SOLDER LUG
ADAU BODY HEIGHT 1.900 INCHES MAXIMUM