TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
21562 GENERAL DYNAMICS OTS AEROSPACE INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
TEST TEST DATA DOCUMENT 16340-11-00067 DRAWING
FEAT SPECIAL FEATURES ONE PRIMARY WINDING; SIX SECONDARY WINDINGS WITH THE FIRST AND FIFTH SECONDARY WINDINGS TAPPED
AKNA INCLOSURE TYPE FULLY INCLOSED
ABFE HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION FUNGUS RESISTANT AND CORROSION RESISTANT
CQLC WINDING TAP LOCATION (NON-CORE) TAP W/O CENTER TAP SINGLE COMPONENT 1ST SECONDARY
ADAU BODY HEIGHT 1.005 INCHES MINIMUM AND 1.025 INCHES MAXIMUM
ABMK OVERALL WIDTH 1.395 INCHES MINIMUM AND 1.415 INCHES MAXIMUM
AARG RELIABILITY INDICATOR NOT ESTABLISHED
TTQY TERMINAL TYPE AND QUANTITY 4 WIRE LEAD AND 12 TAB, SOLDER LUG
ACZB FREQUENCY RATING 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 205.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
ABHP OVERALL LENGTH 1.830 INCHES MINIMUM AND 1.870 INCHES MAXIMUM
ACZF MAXIMUM TRANSFORMER POWER RATING 150.0 WATTS SINGLE COMPONENT
AGAV END ITEM IDENTIFICATION 5805-01-188-3993 CENTRAL OFFICE,TELEPHONE,AUTOMATIC
AXGY MOUNTING METHOD TERMINAL SINGLE GROUP
AEHZ MAXIMUM OPERATING TEMP 160.0 DEG CELSIUS
CRBZ WINDING OPERATING CURRENT 1.6 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE PRIMARY

Similar Parts

726941-1 , 7269411 , 5950-01-324-4292 , 5950013244292 , 013244292