Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
82647 |
SENSATA TECHNOLOGIES INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.703 INCHES NOMINAL |
ADAT |
BODY WIDTH |
0.750 INCHES NOMINAL |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 TAB W/SCREW |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
CORROSION RESISTANT AND EXPLOSION RESISTANT |
THSD |
THREAD SERIES DESIGNATOR |
UNS |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
800.0 AC SINGLE LOCATION AND 2000.0 DC SINGLE LOCATION |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
2.0 AMPERES AC SINGLE LOCATION AND 2.0 AMPERES DC SINGLE LOCATION |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.707 INCHES NOMINAL |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
145.0 SINGLE LOCATION |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
CPRJ |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
ADAQ |
BODY LENGTH |
0.562 INCHES NOMINAL |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
ABXD |
BUSHING LENGTH |
0.250 INCHES NOMINAL |