CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
82647 |
SENSATA TECHNOLOGIES INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE TWO |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
AKPX |
POLE QUANTITY |
3 |
PKWT |
UNPACKAGED UNIT WEIGHT |
0.375 POUNDS |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
THD BUSHING |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
5000.0 AC ALL LOCATIONS |
THSD |
THREAD SERIES DESIGNATOR |
UNS |
ADAT |
BODY WIDTH |
2.000 INCHES MAXIMUM |
ADAQ |
BODY LENGTH |
1.187 INCHES MINIMUM AND 1.249 INCHES MAXIMUM |
ADTV |
CASE MATERIAL |
PLASTIC |
CPRQ |
RESET METHOD |
MANUAL |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
145.0 SINGLE LOCATION |
ADAU |
BODY HEIGHT |
3.105 INCHES MAXIMUM |
CPRJ |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.625 INCHES NOMINAL |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCKPROOF AND VIBRATIONPROOF |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
3.0 AMPERES AC SINGLE LOCATION |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
TTQY |
TERMINAL TYPE AND QUANTITY |
6 SCREW |
FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
AAQL |
BODY STYLE |
MULTIPOLE-SINGLE ACTUATOR TYPE |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
ABXD |
BUSHING LENGTH |
0.250 INCHES MINIMUM AND 0.312 INCHES MAXIMUM |
AEBQ |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH |
0.500 INCHES NOMINAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
120.0 AC SINGLE LOCATION |