Part Number
Definition:
AN ITEM HAVING EITHER A SINGLE TAPPED WINDING (AUTOTRANSFORMER TYPE), OR TWO OR MORE WINDINGS DESIGNED TO FURNISH INDUCTIVE REACTANCE AND/OR TRANSFER ELECTRICAL ENERGY IN CIRCUITS BY MEANS OF A MAGNETIC FIELD. IT IS SO DESIGNED THAT ITS ENTIRE INTENDED RANGE OF OPERATIONS IS ABOVE 20 KILOHERTZ (KILOCYCLES). THE MINIMUM VALUE MAY EXTEND INTO THE AUDIO FREQUENCY RANGE (BELOW 20 KILOHERTZ). IT MAY INCLUDE INTEGRAL CAPACITORS, COILS, RESISTORS, AND ADJUSTABLE TUNING CORES. FOR ITEMS HAVING ONLY TWO ACTIVE TERMINALS SEE COIL, RADIO FREQUENCY. INCLUDES TYPES HAVING WINDINGS WHICH MAY BE MOVED WITH RESPECT TO EACH OTHER. EXCLUDES TRANSFORMER, DISCRIMINATOR.
CAGE Information
Code | Company |
---|---|
21562 | GENERAL DYNAMICS OTS AEROSPACE INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 5 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |
ADAQ | BODY LENGTH | 0.500 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
TTQY | TERMINAL TYPE AND QUANTITY | 26 WIRE LEAD |
ADAR | BODY OUTSIDE DIAMETER | 1.100 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 120.0 DEG CELSIUS |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
FEAT | SPECIAL FEATURES | FIRST AND SECOND PRIMARY CONSIST OF TWO WINDINGS EACH,ALSO FIRST SECONDARY CONSIST OF THREE WINDINGS |