Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
1Q449 |
BLUE SEA SYSTEMS INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
AJEC |
BOSS HEIGHT |
0.150 INCHES NOMINAL |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC-HYDRAULIC SINGLE LOCATION |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
SUPP |
SUPPLEMENTARY FEATURES |
C-SERIES TOGGLE SINGLE POLE;TERMINAL STUDS 1/4INCH-20 STAINLESS STEEL;RATED SWITCH CYLES 10,000 AT RATED AMPS AND VOLTAGE |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
CXCY |
PART NAME ASSIGNED BY CONTROLLING AGENCY |
TOGGLE CIRCUIT BREAKER |
AEBY |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH |
2.062 INCHES NOMINAL |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
2.475 INCHES NOMINAL |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
25.0 AMPERES DC SINGLE LOCATION |
ADAQ |
BODY LENGTH |
2.500 INCHES NOMINAL |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
FEAT |
SPECIAL FEATURES |
THIS IS A DIRECT CURRENT DEVICE-DO NOT MAKE ANY CONNECTIONS TO THE COIL SHUNT;TRIP FREE CANNOT BE HELD CLOSED AFTER TRIP;COMBINES SWITCHING AND CIRCUIT PROTECTION FOR INVERTERS/BOW THRUSTERS/WINDLASSES;PREVIOUSLY ONLY AVAILABLE IN FUSES |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
65.0 DC SINGLE LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 THREADED HOLE |
AGAV |
END ITEM IDENTIFICATION |
MARINE ELECTRICAL APPLICATIONS |
ADAT |
BODY WIDTH |
0.755 INCHES NOMINAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.940 INCHES NOMINAL |
CMLP |
THREAD QUANTITY PER INCH |
32 |
Similar Parts