Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
90536 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.300 INCHES |
ABGS | BASE THICKNESS | 0.250 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | KULKA 600 GP SERIES DOUBLE ROW TERMINAL BLOCK |
ABGN | BOARD OVERALL LENGTH | 3.660 INCHES |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.380 INCHES |
AMPS | CURRENT RATING IN AMPS | 15.0 |
AGAV | END ITEM IDENTIFICATION | ENGINE DSL |
ABGQ | BOARD OVERALL HEIGHT | 0.560 INCHES |
CWLN | TERMINAL DESIGN | LINKED NONFEEDTHRU |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 8 SINGLE |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.560 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.310 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.125 INCHES |
CSCR | TERMINAL CONNECTING LINK TYPE | 18 SINGLE |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 SINGLE |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITH INSULATED STRIP |
ABGP | BOARD OVERALL WIDTH | 0.870 INCHES |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
AAMA | MOUNTING HOLE DIAMETER | 0.180 INCHES |
FEAT | SPECIAL FEATURES | 150 DEG C; SCREWS: NO. 5-40 BINDER HEAD, PHIL-SLOT; WIRE RANGE: NO. 12-22 AWG; TERMINALS ARE PLATED BRASS |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.310 INCHES |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.140 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 8 SINGLE |
AAQL | BODY STYLE | BARRIER TYPE |