Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
19208 | ALLIANCE OIL CORP |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
CQBC | MINIMUM TENSILE STRENGTH | 1450 POUNDS PER SQUARE INCH |
ZZZX | DEPARTURE FROM CITED DESIGNATOR | AS MOD BY ID AND SIZE |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
ZZZT | NONDEFINITIVE SPEC/STD DATA | 9/16 IN. SIZE AND B GRADE AND U FORM AND I CLASS AND UA SUBFORM AND 1 CATEGORY AND F TYPE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJH | TEMP RATING | -46.0 DEG CELSIUS AND 70.0 DEG CELSIUS |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 520.0 VOLTS PER MIL /0.001 INCH/ |
MATL | MATERIAL | PLASTIC, MIL-I-631, TYPE F, FORM U, SUBFORM UA, GRADE B, CLASS 1, CATEGORY 1 |
HUES | COLOR | CLEAR |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
AARX | INSIDE DIAMETER | 0.562 INCHES NOMINAL |
AAGT | WALL THICKNESS | 0.025 INCHES MINIMUM AND 0.035 INCHES MAXIMUM |