Part Number
Definition:
AN ITEM HAVING EITHER A SINGLE TAPPED WINDING (AUTOTRANSFORMER TYPE), OR TWO OR MORE WINDINGS DESIGNED TO FURNISH INDUCTIVE REACTANCE AND/OR TRANSFER ELECTRICAL ENERGY IN CIRCUITS BY MEANS OF A MAGNETIC FIELD. IT IS SO DESIGNED THAT ITS ENTIRE INTENDED RANGE OF OPERATIONS IS ABOVE 20 KILOHERTZ (KILOCYCLES). THE MINIMUM VALUE MAY EXTEND INTO THE AUDIO FREQUENCY RANGE (BELOW 20 KILOHERTZ). IT MAY INCLUDE INTEGRAL CAPACITORS, COILS, RESISTORS, AND ADJUSTABLE TUNING CORES. FOR ITEMS HAVING ONLY TWO ACTIVE TERMINALS SEE COIL, RADIO FREQUENCY. INCLUDES TYPES HAVING WINDINGS WHICH MAY BE MOVED WITH RESPECT TO EACH OTHER. EXCLUDES TRANSFORMER, DISCRIMINATOR.
CAGE Information
Code | Company |
---|---|
79500 | WESTINGHOUSE ELECTRIC CORP |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQNJ | TAP LOCATION IN TURNS | 6.500 SINGLE COMPONENT SINGLE PRIMARY AND 23.750 SINGLE COMPONENT SINGLE PRIMARY |
CQNJ | TAP LOCATION IN TURNS | 6.500 SINGLE COMPONENT SINGLE PRIMARY AND 23.750 SINGLE COMPONENT SINGLE PRIMARY |
ADAQ | BODY LENGTH | 6.500 INCHES NOMINAL |
ACZP | COIL FORM TYPE | SOLID SINGLE COMPONENT |
ADAR | BODY OUTSIDE DIAMETER | 2.750 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB, SOLDER LUG AND 2 THREADED STUD |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.06408 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY |
AKNA | INCLOSURE TYPE | OPEN |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |