Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
03538 | LOCKHEED MARTIN CORPORATION DBA MS2 |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | BLACK |
AARX | INSIDE DIAMETER | 0.032 INCHES MINIMUM AND 0.039 INCHES MAXIMUM |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
ZZZT | NONDEFINITIVE SPEC/STD DATA | UA SUBFORM AND 1 CATEGORY AND U FORM AND A GRADE AND 20 AWG SIZE AND I CLASS AND F TYPE |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AAGT | WALL THICKNESS | 0.013 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL /0.001 INCH/ |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
MATL | MATERIAL | PLASTIC, POLYVINYL CHLORIDE, MIL-I-631, TYPE F, FORM U, GRADE A, CLASS 1, CATEGORY 1 |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND FLAME RESISTANT AND OIL RESISTANT |
ABJH | TEMP RATING | -30.0 DEG CELSIUS AND 75.0 DEG CELSIUS |