Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
03538 | LOCKHEED MARTIN CORPORATION DBA MS2 |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ZZZT | NONDEFINITIVE SPEC/STD DATA | A GRADE AND U FORM AND UA SUBFORM AND 1 CATEGORY AND 1 CLASS AND F TYPE |
MATL | MATERIAL | PLASTIC, POLYVINYL CHLORIDE, MIL-I-631, TYPE F, FORM U, SUBFORM UA, GRADE A, CLASS 1 |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AAGT | WALL THICKNESS | 0.013 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MODIFIED BY COLOR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 800.0 VOLTS PER MIL /0.001 INCH/ |
HUES | COLOR | CLEAR |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
ADZC | ENVIRONMENTAL PROTECTION | MILDEW RESISTANT AND FLAME RESISTANT AND OIL RESISTANT |
AARX | INSIDE DIAMETER | 0.102 INCHES MINIMUM AND 0.112 INCHES MAXIMUM |
ABJH | TEMP RATING | -30.0 DEG CELSIUS AND 75.0 DEG CELSIUS |