Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
97942 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FEAT | SPECIAL FEATURES | INPUT 235 VOLTS PEAK,420 AMP PEAK,0.003 OHMS DCR MAXIMUM,535 V WKG; OUTPUT 6100 VOLTS PEAK,19.2 AMP PEAK,0.500 OHMS DCR MAXIMUM,6100 V WKG FOR WINDINGS 3-5 OUTPUT FOR WINDINGS 6-7 ARE 23 VOLTS PEAK,1A RMS,535 V WKG,0.05 OHMS,MAXIMUM ALTITUDE 10000 FEET,MAXIMUM AMBIENT TEMPERATURE 65 DEGREES C,UNIT DESIGNED TO OPERATE IN TRANSFORMER OIL |
CMLP | THREAD QUANTITY PER INCH | 32 2ND GROUP |
ABMK | OVERALL WIDTH | 7.120 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.086 INCHES 1ST GROUP |
ABKW | OVERALL HEIGHT | 13.750 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES 2ND GROUP |
THSD | THREAD SERIES DESIGNATOR | UNC 2ND GROUP |