Part Number
Definition:
TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
03538 | LOCKHEED MARTIN CORPORATION DBA MS2 |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 20 TWISTED PAIR |
HUES | COLOR | BLACK 10TH POSITION COVER TENTH CONDUCTOR |
HUES | COLOR | YELLOW 4TH POSITION COVER FOURTH CONDUCTOR |
HUES | COLOR | WHITE 9TH POSITION COVER NINTH CONDUCTOR |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 7 ALL CONDUCTORS |
ABJH | TEMP RATING | 80.0 DEG CELSIUS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
HUES | COLOR | VIOLET 7TH POSITION COVER SEVENTH CONDUCTOR |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
HUES | COLOR | BROWN 1ST POSITION COVER FIRST CONDUCTOR |
MATT | MATERIAL | PLASTIC POLYVINYL CHLORIDE 1ST POSITION COATING CABLE |
HUES | COLOR | RED 2ND POSITION COVER SECOND CONDUCTOR |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 36 ALL CONDUCTORS |
HUES | COLOR | BLUE 6TH POSITION COVER SIXTH CONDUCTOR |
MATT | MATERIAL | PLASTIC POLYVINYL CHLORIDE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
HUES | COLOR | ORANGE 3RD POSITION COVER THIRD CONDUCTOR |
HUES | COLOR | GRAY 8TH POSITION COVER EIGHTH CONDUCTOR |
AAGR | CROSS-SECTIONAL SHAPE STYLE | FLAT |
HUES | COLOR | GREEN 5TH POSITION COVER FIFTH CONDUCTOR |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
AMQN | CONDUCTOR QUANTITY | 40 |
AGAV | END ITEM IDENTIFICATION | LGM-30 MISSILE,F-111,C-141,F-117A,OTH-B PROGRAM/FPS-118 |
ADWH | CROSS-SECTIONAL WIDTH | 2.026 INCHES NOMINAL |
CXDC | ROUND CONDUCTOR SIZE | 28 AWG ALL CONDUCTORS |
ADVN | CROSS-SECTIONAL HEIGHT | 0.080 INCHES NOMINAL |