Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
82647 |
SENSATA TECHNOLOGIES INC |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
ADAQ |
BODY LENGTH |
1.781 INCHES NOMINAL |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
1000.0 DC SINGLE LOCATION |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
0.700 MINIMUM AT 200 PCT SINGLE LOCATION AND 2.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
CPRJ |
TRIP RELEASE METHOD |
MAGNETIC SINGLE LOCATION |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
1.341 INCHES NOMINAL |
THSD |
THREAD SERIES DESIGNATOR |
UNS |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
32.0 DC SINGLE LOCATION |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
FUNGUS RESISTANT AND CORROSION RESISTANT AND DUSTPROOF AND SANDTIGHT |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
10.0 AMPERES DC SINGLE LOCATION |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SHUNT TRIP SINGLE LOCATION |
ADAT |
BODY WIDTH |
0.656 INCHES NOMINAL |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
135.0 SINGLE LOCATION |
APNQ |
ARC QUENCHING METHOD |
MAGNETIC BLOWOUT |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING W/PANEL SEAL |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.669 INCHES NOMINAL |
ABXD |
BUSHING LENGTH |
0.250 INCHES NOMINAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
3 TAB W/SCREW |
Similar Parts