Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
HUES | COLOR | BLACK |
HUES | COLOR | BLACK |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MOD BY COLOR |
FLEX | FLEXIBILITY | FLEXIBLE |
AAGT | WALL THICKNESS | 0.030 INCHES MINIMUM AND 0.040 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AARX | INSIDE DIAMETER | 0.875 INCHES MINIMUM AND 0.911 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | FLAME RESISTANT AND MILDEW RESISTANT AND OIL RESISTANT |
STYL | STYLE DESIGNATOR | NONSHRINKABLE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 525.0 VOLTS PER MIL /0.001 INCH/ |
ZZZT | NONDEFINITIVE SPEC/STD DATA | I CLASS AND UA SUBFORM AND 1 CATEGORY AND U FORM AND A GRADE AND 7/8 IN. SIZE AND F TYPE |
CQBC | MINIMUM TENSILE STRENGTH | 1800 POUNDS PER SQUARE INCH |
MATL | MATERIAL | PLASTIC, POLYVINYL CHLORIDE, MIL-I-631, TYPE F, FORM U, GRADE A, CLASS 1, CATEGORY 1 |
ABJH | TEMP RATING | -30.0 DEG CELSIUS AND 75.0 DEG CELSIUS |