Part Number
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
16428 | BELDEN WIRE & CABLE COMPANY LLC DBA |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | PAIRED-LOW CAPACITANCE COMPUTER CABLE |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
CXDC | ROUND CONDUCTOR SIZE | 22 AWG ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYVINYL CHLORIDE CORE PRIMARY INSULATION ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 7 ALL CONDUCTORS |
ABJH | TEMP RATING | 80.0 DEG CELSIUS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYVINYLIDENE CHLORIDE 1ST POSITION PRIMARY INSULATION OVERALL |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 300.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
AGAV | END ITEM IDENTIFICATION | OA-9233A/G, OPERATIONS GROUP VAN |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.384 INCHES NOMINAL |
AMQN | CONDUCTOR QUANTITY | 16 |
MATT | MATERIAL | PLASTIC POLYVINYLIDENE CHLORIDE 3RD POSITION JACKET OVERALL |
MATT | MATERIAL | COPPER 2ND POSITION SHIELD BRAID, METALLIC OVERALL AND ALUMINUM 2ND POSITION SHIELD BRAID, METALLIC OVERALL |
FEAT | SPECIAL FEATURES | 8 PAIRS OF CONDUCTORS COLOR CODED; 1ST PAIR=BLACK & RED; 2ND PAIR=BLACK & WHITE; 3RD PAIR=BLACK & GREEN; 4TH PAIR=BLACK & BLUE; 5TH PAIR=BLACK & YELLOW; 6TH PAIR=BLACK & BROWN; 7TH PAIR=BLACK & ORANGE; 8TH PAIR=RED & WHITE; BULK CABLE WEIGHT: 94LBS/1000FT; MIN. BEDING RADIUS 3.9 IN; UL AWM STYLE 2. |
CXDT | GROUP QUANTITY | 8 |