Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
89536 | FLUKE CORPORATION |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADZC | ENVIRONMENTAL PROTECTION | SPRAY TIGHT |
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN ALL FUNCTIONS |
AKDX | WINDING QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 0.413 INCHES NOMINAL |
APNA | WINDING DC RESISTANCE RATING | 83.0 OHMS NOMINAL SINGLE WINDING |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
APCN | COIL QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 TERMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 5.0 VOLTS TEARDROP, TWO HOLES TYPE 4F ALL WINDINGS |
ABMK | OVERALL WIDTH | 0.433 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABHP | OVERALL LENGTH | 0.795 INCHES NOMINAL |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES DC RESISTIVE LOAD |
CRXH | TIME DELAY | 0.01 SECONDS NOMINAL FIXED OPERATE TIME |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 380.0 AC |