Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , ROTARY
Definition:
A SWITCH ACTUATED BY A DEFINITE ANGULAR ROTATION OF THE SWITCH SHAFT ABOUT ITS AXIS. FOR ITEMS HAVING RATED ACTUATION TRAVEL AND PRESSURE CHARACTERISTICS, SEE SWITCH, SENSITIVE. EXCLUDES RELAY, ROTARY; SWITCH, STEPPING; AND SWITCH, TELEPHONE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
90827 | DYNA-EMPIRE INC |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
SUPP | SUPPLEMENTARY FEATURES | 1 AMPERE AT 28 VOLTS D.C. OR .5 AMPERE AT 110 VOLTS A.C. DIELECTRIC CONSTANT 5.58, DIELECTRIC LOSS FACTOR .00419, DISSIPATION FACTOR .00075 |
CSLC | SWITCH ACTUATOR POSITIONING INCREMENT | 60.0 DEGREES SINGLE ACTUATOR |
THSD | THREAD SERIES DESIGNATOR | UNEF SINGLE MOUNTING FACILITY |
AASA | THREAD LENGTH | 0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 110.0 AC AT SEA LEVEL |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CRSJ | SHAFT TYPE | ROUND, FLATTED SINGLE ACTUATOR |
ABNB | FIRST FLAT LENGTH | 0.313 INCHES NOMINAL SINGLE ACTUATOR |
CQMK | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL |
ABNC | FLAT HEIGHT | 0.219 INCHES NOMINAL SINGLE ACTUATOR |
AXGY | MOUNTING METHOD | THREADED BUSHING SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 2.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.250 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | CIRCULAR WAFER, BUSHING MOUNT |
ABWV | SHAFT DIAMETER | 0.250 INCHES NOMINAL SINGLE ACTUATOR |
ABKW | OVERALL HEIGHT | 1.312 INCHES NOMINAL |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES SINGLE MOUNTING FACILITY |
ABXF | SHAFT LENGTH | 0.875 INCHES NOMINAL SINGLE ACTUATOR |
CRJH | SWITCH ACTUATOR INDEXING POSITION QUANTITY | 2 SINGLE ACTUATOR |
FEAT | SPECIAL FEATURES | FOR CIRCUITS REQUIRING HIGHER RATINGS, SILVER-ALLOY AND HIGH-TEMPERATURE CONTACTS WILL BREAK CURRENT ON A RESISTIVE LOAD OF 2 AMPERE AT 28 VOLTS D.C. OR 1 AMPERE AT 110 VOLTS A.C WITH A MINIMUM RELIABLE LIFE OF 50,000 OPERATIONS |
AFBH | INDIVIDUAL SECTION QUANTITY | 2 |