Part Number
Definition:
AN ITEM CONSISTING OF INSULATING MATERIAL, WHICH IS SPECIFICALLY DESIGNED TO HAVE FASTENED THEREON, OR ON WHICH ARE FASTENED TERMINAL(S), SUCH AS SCREWS, SOLDER LUGS, SOLDER STUDS, SOLDERLESS CONNECTORS, CLIPS, AND THE LIKE. IT IS USUALLY USED FOR JUNCTIONS OR TERMINATIONS OF WIRE OR CABLE ASSEMBLIES. IT DOES NOT INCLUDE ITEMS AS DEFINED ABOVE WITH PARTS, SUCH AS RESISTORS AND CAPACITORS MOUNTED THEREON. DO NOT USE IF A MORE SPECIFIC NAME EXISTS, SUCH AS FUSEHOLDER; HOLDER, RESISTOR; FANNING STRIP; CONTACT ASSEMBLY, ELECTRICAL; JACK ASSEMBLY, TIP; CHAMBER, CABLE TERMINAL; PANEL (2) (AS MODIFIED); CONNECTOR (AS MODIFIED). EXCLUDES TERMINAL, STUD; TERMINAL, FEEDTHRU, INSULATED; POST, BINDING, ELECTRICAL; AND CHASSIS, ELECTRICAL-ELECTRONIC EQUIPMENT. FOR ITEMS HAVING PRINTED ELECTRICAL CONDUCTOR PATHS, SEE PRINTED WIRING BOARD.
CAGE Information
Code | Company |
---|---|
80064 | NAVAL SHIP SYSTEMS COMMAND |
Federal Supply Class
Title
LUGS, TERMINALS, AND TERMINAL ST
Inclusions:
INCLUDES BINDING POSTS; BATTERY CLIPS; STUD TERMINALS; TEST CLIPS.
Exclusions:
EXCLUDES CAPS, ELECTRICAL; CLIPS, ELECTRICAL; AND CONTACTS, ELECTRICAL.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.750 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.781 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.938 INCHES |
ABCS | TERMINAL ROW QUANTITY | 2 |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.844 INCHES |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 4 SINGLE |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.100 INCHES |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | MIL-M-14,TYPE MAI-60 MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.844 INCHES |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
ABGN | BOARD OVERALL LENGTH | 1.875 INCHES |
ABGP | BOARD OVERALL WIDTH | 1.375 INCHES |
CRNL | NONFEEDTHRU TERMINAL TYPE | 597 SINGLE |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.625 INCHES |
ABCX | BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
MATT | MATERIAL | PLASTIC POLYESTER BOARD AND GLASS FIBER BOARD |
AAMA | MOUNTING HOLE DIAMETER | 0.156 INCHES |
ABGS | BASE THICKNESS | 0.500 INCHES |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
AAQL | BODY STYLE | BARRIER TYPE |