Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
1LQK8 AGILENT TECHNOLOGIES INC. DIV AGILEN

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY OR 600.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 7.5 AMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY
CBME CUBIC MEASURE (NON-CORE) 89.3 CUBIC INCHES
ABTB MOUNTING HOLE DIAMETER 0.177 INCHES MINIMUM SINGLE GROUP AND 0.197 INCHES MAXIMUM SINGLE GROUP
ACZB FREQUENCY RATING 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT
AKNA INCLOSURE TYPE FULLY INCLOSED
ABMK OVERALL WIDTH 3.812 INCHES MAXIMUM
CRMJ WINDING POWER RATING 15.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
CRBZ WINDING OPERATING CURRENT 300.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY
CRMJ WINDING POWER RATING 66.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
FEAT SPECIAL FEATURES 2 PRIMARY WINDINGS; 8 SECONDARY WINDINGS
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.984 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.016 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BPLC WINDING FUNCTION AND QUANTITY 2 PRIMARY SINGLE COMPONENT AND 8 SECONDARY SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 3.0 AMPERES NOMINAL B SINGLE COMPONENT 4TH SECONDARY
CRBZ WINDING OPERATING CURRENT 130.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRMJ WINDING POWER RATING 78.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
ABHP OVERALL LENGTH 4.937 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
ABKW OVERALL HEIGHT 4.749 INCHES MAXIMUM
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
CRMJ WINDING POWER RATING 47.25 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 1ST SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 220.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
CBBL FEATURES PROVIDED COLOR CODED LEAD
TTQY TERMINAL TYPE AND QUANTITY 21 WIRE LEAD
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.859 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.922 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP

Similar Parts

9100-0098 , 91000098 , 5950-00-899-8405 , 5950008998405 , 008998405