Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
90536 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 105.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ABTD | MOUNTING SLOT WIDTH | 0.276 INCHES MINIMUM SINGLE GROUP AND 0.286 INCHES MAXIMUM SINGLE GROUP |
CRMJ | WINDING POWER RATING | 1.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 6 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 6.730 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 6.770 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.980 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.020 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAU | BODY HEIGHT | 7.500 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 11.000 INCHES MAXIMUM |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
ADAQ | BODY LENGTH | 9.940 INCHES MAXIMUM |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAT | BODY WIDTH | 6.000 INCHES MAXIMUM |