Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
58657 | LEACH INTERNATIONAL CORPORATION DBA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
CRXH | TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 440.0 AC AND 28.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CRXH | TIME DELAY | 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.213 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.223 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC INDUCTIVE LOAD AND 50.0 AMPERES DC INDUCTIVE LOAD |
ABKW | OVERALL HEIGHT | 2.297 INCHES MINIMUM AND 2.485 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL OR 400.0 NOMINAL |
APNQ | ARC QUENCHING METHOD | AIR |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
ABMK | OVERALL WIDTH | 3.150 INCHES NOMINAL |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.240 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 3.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD ALL FUNCTIONS |
APNP | DUTY TYPE | CONTINUOUS |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 200.0 MILLIAMPERES AC SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12.0 AMPERES AC MOTOR LOAD AND 50.0 AMPERES DC MOTOR LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
ABHP | OVERALL LENGTH | 3.730 INCHES MAXIMUM |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.677 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.697 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |