Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
18876 U S ARMY AVIATION AND MISSILE COMMAN

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAU BODY HEIGHT 4.375 INCHES NOMINAL
ABKW OVERALL HEIGHT 5.250 INCHES NOMINAL
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
BPLC WINDING FUNCTION AND QUANTITY 2 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 13.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRBZ WINDING OPERATING CURRENT 300.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 260.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CRBZ WINDING OPERATING CURRENT 300.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY
CQJX NOMINAL THREAD SIZE 0.164 INCHES SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 260.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
AKNA INCLOSURE TYPE HERMETICALLY SEALED
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 13.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 1ST PRIMARY
ADAQ BODY LENGTH 3.250 INCHES NOMINAL
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT 1ST SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 14 TURRET
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
ACZB FREQUENCY RATING 380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT
ADAT BODY WIDTH 3.250 INCHES NOMINAL
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY

Similar Parts

9197878 , 9197878 , 5950-00-812-2220 , 5950008122220 , 008122220