Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
73138 | BI TECHNOLOGIES CORPORATION |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 190.0 NOMINAL |
AAPN | SECTION QUANTITY | 1 |
CBME | CUBIC MEASURE | 0.023 CUBIC INCHES |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0/+20.0 SINGLE SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 250.000 PERCENT, RATED AMPERES C AND BETTER FLOORING |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 40.0 SINGLE SECTION |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 NOMINAL INCHES |
AAQL | BODY STYLE | CYLINDRICAL |
AEFM | MAXIMUM STOP TORQUE | 12.00 INCH-OUNCES |
ADAQ | BODY LENGTH | 0.200 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 1.800 INCHES MINIMUM |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 190.0 NOMINAL |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 7TH SECONDARY QUALITY |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
AEFL | MAXIMUM RUNNING TORQUE | 6.00 INCH-OUNCES |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |
ABPM | BODY DIAMETER | 0.375 NOMINAL CENTIMETERS |