Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
73138 | BI TECHNOLOGIES CORPORATION |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAQ | BODY LENGTH | 0.250 INCHES MAXIMUM |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 190.0 NOMINAL |
AAPN | SECTION QUANTITY | 1 |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
AEFK | MAXIMUM STARTING TORQUE | 6.00 INCH-OUNCES |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0/+20.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 40.0 SINGLE SECTION |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION |
AAQL | BODY STYLE | CYLINDRICAL |
AEFM | MAXIMUM STOP TORQUE | 12.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
ABJT | TERMINAL LENGTH | 0.180 INCHES MINIMUM |
APXH | TERMINAL LOCATION | REAR END |
CBBL | FEATURES PROVIDED | HUMIDITY PROOF |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 500.0 KILOHMS SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
ABPM | BODY DIAMETER | 0.375 INCHES NOMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |