Part Number
Definition:
A SPECIFIC ELECTRICAL ELEMENT OR SET OF ELECTRICAL ELEMENTS THAT ARE CONNECTED TOGETHER TO FORM A FIXED ARRANGEMENT AND USED AS A SUBSTITUTE LOAD FOR TERMINATING AN ELECTRICAL CIRCUIT. A DUMMY LOAD CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT BUT DOES NOT FUNCTION IN THE SAME MANNER AS THE LOAD WHICH IT REPLACES. EXAMPLES ARE RESISTORS USED TO REPLACE ANTENNAS, BATTERIES, LOUDSPEAKERS, OR THE LIKE. INCLUDES SINGLE PORT TERMINATIONS OF TWIN LEAD, COAXIAL AND WAVEGUIDE TRANSMISSION LINES AS LOW POWER TERMINATIONS OF A SECTION OF A TRANSMISSION SYSTEM IN A SPECIFIED MANNER. INCLUDES DUMMY LOADS WHEN ARRANGED IN A GROUP OR BANK. EXCLUDES POWER ABSORBERS. SEE ALSO LOAD BANK, ELECTRICAL.
CAGE Information
Code | Company |
---|---|
82577 | RAYTHEON COMPANY DBA RAYTHEON |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKSA | WAVEGUIDE FLANGE DESIGNATION | UG135/U |
AJDB | POWER RATING | 500.000 WATTS AVERAGE AND 290.000 KILOWATTS PEAK |
BFMF | COOLING METHOD | SELF-COOLED |
AWNC | INTERNAL OPERATING PRESSURE | 30.0 POUNDS PER SQUARE INCH GAGE |
ADAT | BODY WIDTH | 2.750 INCHES NOMINAL |
ARNH | OPERATING POSITION | HORIZONTAL |
STYL | STYLE DESIGNATOR | WAVEGUIDE MOUNTED |
ACYW | IMPEDANCE RATING IN OHMS | NOT RATED |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
AKRZ | TERMINATION TYPE | WAVEGUIDE FLANGE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AFGQ | FREQUENCY RANGE RATING | +8.200/+12.400 GIGAHERTZ |
ABHP | OVERALL LENGTH | 5.690 INCHES MAXIMUM |