Part Number
Definition:
AN ENCLOSURE WHICH INCLUDES, MOUNTS, AND PROTECTS ONE OR MORE CIRCUIT BREAKERS. IT IS DESIGNED FOR AND MAY INCLUDE A COVER AND SUCH ACCESSORIES AS MOUNTING HARDWARE, BRACKETS, AND CONDUIT FITTINGS. MAY INCLUDE TERMINAL BOARDS AND/OR BUS CONDUCTORS USED AS A CONVENIENCE FOR TERMINATING THE CIRCUIT BREAKERS. MAY INCLUDE HANDLE TIE BARS. IT IS USUALLY USED AS A LOAD CENTER FOR THE PROTECTION OF CERTAIN ELECTRICAL DEVICES SUCH AS WATER HEATERS, MOTORS, ETC., OR AS A SERVICE CENTER FOR HOMES OR OFFICES. FOR BOXES WHICH INCLUDE ONLY SWITCHES, JACKS, FUSEHOLDERS, TERMINALS AND/OR TERMINAL BOARDS OR FUSEHOLDERS, OR ANY COMBINATION OF THESE DEVICES, SEE SWITCH BOX; JACK BOX; TERMINAL BOX; AND DISTRIBUTION BOX. FOR BOXES DESIGNED TO MOUNT AND PROTECT BUT DO NOT INCLUDE CIRCUIT BREAKERS, SEE CIRCUIT BREAKER BOX SUBASSEMBLY. SEE ALSO INTERCONNECTING CABINET; PANEL, POWER DISTRIBUTION; JUNCTION BOX; AND CABINET, ELECTRICAL EQUIPMENT.
CAGE Information
Code | Company |
---|---|
94259 | WESTINGHOUSE ELECTRIC CORP BETTIS AT |
Federal Supply Class
Title
CIRCUIT BREAKERS
Inclusions:
INCLUDES CIRCUIT BREAKERS AND CUTOUTS.
Exclusions:
EXCLUDES RELAYS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 5.998 INCHES NOMINAL |
MATT | MATERIAL | PLASTIC |
CRTL | CRITICALITY CODE JUSTIFICATION | ZZZY |
BGJL | CIRCUIT BREAKER TYPE AND QUANTITY | 1 DOUBLE POLE |
BFYD | MAIN LINE MAXIMUM AC VOLTAGE RATING IN VOLTS | 600.0 |
ABFY | OVERALL DEPTH | 4.140 INCHES NOMINAL |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | REFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO3498 |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.437 INCHES NOMINAL |
BFYC | MAIN LINE MAXIMUM CURRENT RATING IN AMPS | 100.0 |
BGJM | CIRCUIT BREAKER CURRENT RATING IN AMPS | 15.0 |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | COVER |
AGEJ | SYSTEM FOR WHICH DESIGNED | THREE WIRE TWO PHASE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 2.937 INCHES NOMINAL |
AESL | STANDARD MOUNTING PATTERN DESIGNATOR | 4 POINT-RECTANGULAR |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTTIGHT-NEMA TYPE 5 |
ABMK | OVERALL WIDTH | 4.468 INCHES NOMINAL |
STYL | STYLE DESIGNATOR | SQUARE, SURFACE MOUNTING |